Close Go back Collapse all sections
Process Data set: Building integrated photovoltaic (BIPV) module - ERS-0191 (130W) (en) en da

Key Data Set Information
Location RER
Geographical representativeness description Product expected to receive waste treatment in Germany
Reference year 2023
Name
Building integrated photovoltaic (BIPV) module - ERS-0191 (130W)
General comment on data set The product assessed in this study is the BIPV module, ERS-0191 (130W), produced by Ennogie ApS. The nominal power per 1 m² is 175 Wp. The product is a building integrated photovoltaic module (BIPV) with the function of producing electricity and waterproofing the building envelope. The BIPV module consists of a frameless mono c-SI photovoltaic laminate with a black surface, which provides a coherent black aesthetic. In comparison to a traditional photovoltaic module, the ERS-0191 replaces the roof itself. When installed, the modules will overlap both vertically and horizontally hence providing a waterproof building envelope as any other roof with the added benefit of producing electricity.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Time representativeness
Data set valid until 2028
Technological representativeness

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 331.6
  • 0.3626
  • 23.95
  • 0
  • 0.3096
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02415
  • 0.6879
  • 4.726
  • 0.04952
  • -27.04
Input
  • 23.68
  • 0
  • -23.68
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 355.2
  • 0.3626
  • 0.2753
  • 0
  • 0.3096
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02415
  • 0.6879
  • 4.726
  • 0.04952
  • -27.04
Input
  • 1865
  • 21.46
  • 7.553
  • 0
  • 53.68
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.293
  • 48.8
  • 92.93
  • 2.251
  • -144.1
Input
  • 57.28
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -57.28
  • 0
  • 0
Input
  • 1922
  • 21.46
  • 7.553
  • 0
  • 53.68
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.293
  • 48.8
  • 35.65
  • 2.251
  • -144.1
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 4.231
  • 0.002713
  • 0.001785
  • 0
  • 0.008085
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000245
  • 0.005443
  • 0.02993
  • 0.002713
  • -0.1172
Output
  • 0.124
  • 0.00005757
  • 0.00001873
  • 0
  • 0.000147
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001176
  • 0.0001274
  • 0.0000336
  • 0.000002555
  • -0.00021
Output
  • 26.17
  • 0.91
  • 0.1111
  • 0
  • 0.07193
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00574
  • 2.51
  • 4.391
  • 15.88
  • -1.834
Output
  • 0.004337
  • 0.0001439
  • 0.00004672
  • 0
  • 0.000371
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002958
  • 0.0003307
  • 0.0001426
  • 0.0000151
  • -0.000455
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.1724
  • 0
  • 0.2429
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.223
  • 0
  • 0
Output
  • 1.285
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.22
  • 0
  • 4.976
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 16.32
  • 0
  • 0
Output
  • 0.8249
  • 0
  • 18.66
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 30.47
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 1.036
  • 0.005723
  • 0.002223
  • 0
  • 0.01675
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00134
  • 0.01311
  • 0.0231
  • 0.0006913
  • -0.112
  • 0.00002054
  • 3.238E-7
  • 9.66E-8
  • 0
  • 8.365E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.685E-8
  • 7.473E-7
  • 1.566E-7
  • 3.413E-8
  • -6.3E-7
  • 0.05831
  • 0.000108
  • 0.0001559
  • 0
  • 0.000122
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000009695
  • 0.0002082
  • 0.002782
  • 0.00000434
  • -0.01418
  • 0.2455
  • 0.001664
  • 0.0007945
  • 0
  • 0.006108
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0004883
  • 0.003938
  • 0.00336
  • 0.001724
  • -0.0126
  • 2.353
  • 0.0182
  • 0.00826
  • 0
  • 0.06703
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005355
  • 0.04305
  • 0.0343
  • 0.002853
  • -0.1313
  • -2.089
  • 0.001383
  • 1.526
  • 0
  • 0.001502
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001174
  • 0.002905
  • 0.2298
  • 0.0003833
  • -0.5863
  • 167.5
  • 1.438
  • 0.6297
  • 0
  • 3.954
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.3162
  • 3.228
  • 6.093
  • 0.1444
  • -11.41
  • 0.1656
  • 0.0006773
  • 0.0002153
  • 0
  • 0.000392
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003133
  • 0.001267
  • 0.003815
  • 0.00001907
  • -0.01312
  • 165.6
  • 1.44
  • 2.155
  • 0
  • 3.956
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.3164
  • 3.232
  • 6.326
  • 0.1449
  • -12.01
  • 0.8202
  • 0.005582
  • 0.002397
  • 0
  • 0.02013
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001603
  • 0.01321
  • 0.00882
  • 0.0008312
  • -0.042
  • 168.5
  • 0.07105
  • 0.02467
  • 0
  • 0.2991
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00672
  • 0.1461
  • 0.6909
  • 0.01225
  • -2.294

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 5871
  • 17.51
  • 5.376
  • 0
  • 31.43
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.512
  • 38.09
  • 170.7
  • 1.503
  • -740.4
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.682E-7
  • 6.405E-10
  • 4.025E-10
  • 0
  • 3.57E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.853E-10
  • 1.234E-9
  • 5.18E-9
  • 3.185E-11
  • -3.85E-8
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000006562
  • 1.768E-8
  • 7.472E-9
  • 0
  • 2.852E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.275E-9
  • 3.99E-8
  • 3.22E-7
  • 6.912E-10
  • -0.000001103
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 10.21
  • 0.1139
  • 0.05022
  • 0
  • 0.242
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01943
  • 0.251
  • 0.4058
  • 0.01106
  • -1.284
Potential Soil quality index (SQP) 2
  • 965.1
  • 12.68
  • 1.808
  • 0
  • 6.847
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5467
  • 33.53
  • 14.4
  • 5.047
  • -77.14
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00001303
  • 1.071E-7
  • 4.252E-8
  • 0
  • 3.885E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.115E-8
  • 2.782E-7
  • 1.109E-7
  • 1.519E-8
  • -5.075E-7